NEW QUESTION # 10
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?
- A. Enable the Collect System Inventory On Restart (CSIOR) attribute
- B. Configure servers to access the remote firmware repository
- C. Enable the Match Firmware of Replaced Part setting in the system BIOS
- D. Install and configure a repository manager
Answer: B
NEW QUESTION # 11
Which card connects to the PCI bus, is physically smaller than a on the system board of a Dell EMC PowerEdge 14G server?
- A. FPGA
- B. OCP
- C. PCIe
- D. NDC
Answer: C
NEW QUESTION # 12
A technician working with a Dell EMC PowerEdge 1 take corrective action?
- A. Check the System Event Log
Check PSU LED
Do a virtual reseat of the iDRAC - B. Check the LCC Log
Check PSU LED
Reseat the CPU - C. Check the LCC Log
Check PSU LED
Reseat the PSU - D. Check the System Event Log
Check PSU LED
Reseat the PSU
Answer: A
NEW QUESTION # 13
What is required for iDRAC Direct 2.0 to connect with IDRAC9 interfaces such as RACADM and WSMAN?
- A. NFC connection
- B. Wi-Fi connection
- C. Ethernet cable
- D. Micro-AB USB
Answer: D
NEW QUESTION # 14
What can be done using in-band management?
- A. Firmware and driver updates
- B. Network bandwidth optimization
- C. Agentless discovery
- D. Remote access
Answer: D
NEW QUESTION # 15
A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?
- A. The iDRAC cannot be rolled back and the LCC cannot be rolled back
- B. The LCC can be rolled back; the iDRAC cannot be rolled back
- C. The iDRAC can be rolled back; the LCC cannot be rolled back
- D. Both the iDRAC and the LCC can be rolled back
Answer: D
NEW QUESTION # 16
A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?
- A. Use a configuration option to convert BOSS to a virtual vFlash
- B. Reuse an existing vFlash SD card from either a 13G or 14G server
- C. Reuse an existing vFlash SD card from a 14G server
- D. Use a configuration option to convert an NVMe drive to a virtual vFlash
Answer: C
NEW QUESTION # 17
Which mobile devices are supported by Quick Sync 2.0 in 14G PowerEdge servers?
- A. iOS, Android, and Windows Phone devices
- B. Android devices only
- C. iOS devices only
- D. iOS and Android devices only
Answer: D
NEW QUESTION # 18
What are key values related to systems management when deploying OpenManage Enterprise wit Dell EMC PowerEdge servers?
- A. Simplify
Unify
Automate
Secure - B. Simplify
Basic Hardware Element Management
Agent-free Management
Fee-based license - C. Automate
Basic Hardware Element Management
Agent-free Management
Simple and effective - D. Simplify
Fee-based license Agent-free Management Secure
Answer: D
NEW QUESTION # 19
A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?
- A. The iDRAC cannot be rolled back and the LCC cannot be rolled back
- B. Both the iDRAC and the LCC can be rolled back
- C. The LCC can be rolled back; the iDRAC cannot be rolled back
- D. The iDRAC can be rolled back; the LCC cannot be rolled back
Answer: C
NEW QUESTION # 20
A system engineer has a 14G Dell EMC Poweredge server with an amber light blinking. The engineer must pull a SupportAssist collection before calling Dell Support to evaluate what the potential problem. Use the simulator to collect and view the SupportAssist collection.
Answer:
Explanation:
Send us your suggestion for this simulation task.
NEW QUESTION # 21
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC What should the technician do to verify iDRAC connectivity on each server?
- A. Ethernet port LOM1 is cabled and the link light is green.
- B. iDRAC Enterprise license is installed
- C. iDRAC dedicated NIC port is cabled and the link light is green
- D. iDRAC Datacenter license is installed.
Answer: A
NEW QUESTION # 22
Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?
- A. 14G
- B. 11G
- C. 13G
- D. 12G
Answer: C
NEW QUESTION # 23
Match each RAID level to its characteristic.
Answer:
Explanation:
NEW QUESTION # 24
A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in App Direct mode. What is the minimum size DIMM supported for this type of memory?
- A. 512 GB
- B. 256 GB
- C. 128 GB
- D. 64 GB
Answer: C
NEW QUESTION # 25
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?
- A. Enable the Collect System Inventory On Restart (CSIOR) attribute
- B. Configure servers to access the remote firmware repository
- C. Enable the Match Firmware of Replaced Part setting in the system BIOS
- D. Install and configure a repository manager
Answer: C
NEW QUESTION # 26
Match each RAID level to its characteristic.
Answer:
Explanation:
NEW QUESTION # 27
What is a characteristic of out-of-band management?
- A. Less secure
- B. Dependent upon OS
- C. Dedicated device
- D. Agent based
Answer: C
NEW QUESTION # 28
Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition.
Answer:
Explanation:
NEW QUESTION # 29
What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?
- A. Ensures that the installed operating system is authentic
- B. Ensures that the server boots only when connected to a verified network
- C. Ensures that no unauthorized BIOS or firmware codes are run
- D. Ensures that the server has a valid Service Tag number
Answer: C
NEW QUESTION # 30
How can a technician know whether IDRAC9 System Lockdown mode is enabled?
- A. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots
- B. Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots
- C. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots
- D. Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots
Answer: B
NEW QUESTION # 31
What can be done using in-band management?
- A. Firmware and driver updates
- B. Network bandwidth optimization
- C. Agentless discovery
- D. Remote access
Answer: B
NEW QUESTION # 32
How can the ePSA be accessed?
- A. OMSA
- B. VMware vSphere plug-in
- C. iDRAC
- D. Lifecycle Controller
Answer: C
NEW QUESTION # 33
......
EMC DES-4122 exam covers a wide range of topics related to PowerEdge servers, including server deployment, configuration, management, and troubleshooting. Candidates will be tested on their ability to install and configure PowerEdge servers, as well as their knowledge of server management tools and techniques. They will also be required to demonstrate their ability to troubleshoot server issues and implement solutions to address them.
EMC DES-4122 certification is a valuable asset for IT professionals who are looking to advance their careers in server administration, virtualization, and cloud computing. Specialist - Implementation Engineer, PowerEdge Exam certification is recognized by some of the biggest names in the IT industry, including Dell Technologies, VMware, and Microsoft. Specialist - Implementation Engineer, PowerEdge Exam certification validates the candidate's ability to implement and manage PowerEdge servers, which are widely used in enterprise data centers and cloud computing environments.
Actual DES-4122 Exam Recently Updated Questions with Free Demo: https://www.prepawaytest.com/EMC/DES-4122-practice-exam-dumps.html
Free EMC DES-4122 Exam Questions: https://drive.google.com/open?id=1g63dMV9lg2AVWd7MS4qL7o6hRZZWW4VO