H19-371_V1.0-ENU Dumps (2023) Prepare Your Exam With 566 Questions
New H19-371_V1.0-ENU Dumps - Real Huawei Exam Questions
NEW QUESTION # 54
What are the options in the typical configuration of FusionModule800?
- A. Temperature and humidity, door sensor, water immersion, smoke sensor, mobile phone APP
- B. Smoke sensor, door sensor, water immersion, SMS alarm, pad
- C. Water immersion, door sensor, video, backup power, ibattery
Answer: B
NEW QUESTION # 55
FusionModule1000A V2R3 version uses Huawei UPS5000E as IT load power supply
- A. True
- B. False
Answer: B
NEW QUESTION # 56
The integrated UPS/integrated power distribution cabinet/precision power distribution cabinet of FusionModule2000 can detect the temperature of branch terminals through NTC probes.
This function is optional and unique to Huawei.
- A. False
- B. True
Answer: B
NEW QUESTION # 57
The integrated UPS rack frame is available in 50Kva and 125Kva ( ).
- A. False
- B. True
Answer: B
NEW QUESTION # 58
The UPS used by FusionPower (prefabricated power module) is ( ).
- A. UPS5000-A
- B. UPS5000-E
- C. UPS5000-H
- D. PS5000-S
Answer: C
NEW QUESTION # 59
Fusion Module500&Fusion Module800 - - Reasons for the typical configuration scheme recommended to customers ( ).
- A. The typical configuration solution has a shorter lead time than the customized solution
- B. Typical configuration solutions are better than customized solutions
- C. The existing typical configuration scheme can basically cover most of the small computer room usage scenarios.
- D. Typical solutions are more competitive
Answer: A,B,C,D
NEW QUESTION # 60
The UPS5000-E has strong load adaptability, and the capacitive/inductive load is super strong/lag ( ) without derating.
- A. 0.5
- B. 0.7
- C. 0.6
- D. 0.4
Answer: A
NEW QUESTION # 61
A system is configured with 15min battery backup time, and the discharge termination voltage of the battery cell should be selected ( ).
- A. 1.75V
- B. 1.80V
- C. 1.67V D .1.60V
Answer: C
NEW QUESTION # 62
Where is the UPS of Chongqing Airport used?
- A. Other
- B. Terminal
- C. Lighting run-up
Answer: B
NEW QUESTION # 63
In UPS5000S, the adjustable range of the number of battery cells in a single group is
- A. Sections 30 to 44
- B. Sections 30 to 48
- C. Sections 30 to 42
- D. Sections 30 to 46
Answer: B
NEW QUESTION # 64
What are the fire linkage functions of FusionModule2000? (multiple choice)
- A. Channel light on
- B. UPS is powered off
- C. Sunroof Flip
- D. Air conditioner off
- E. The access door is magnetically opened
Answer: A,C,D,E
NEW QUESTION # 65
Compared with NXR, which indicators below UPS5000-A (30kVA120kVA) have advantages ( )
- A. Rack Tower Compatible
- B. 40 degrees without derating
- C. Input voltage range
- D. Output Power Factor
Answer: A,B,C,D
NEW QUESTION # 66
What kind of access control can the rear door of the FusionModule2000 cabinet support?
- A. IC card swipe access control
- B. Three-in-one access control
- C. None of the above
- D. Mechanical code lock
Answer: C
NEW QUESTION # 67
The operating temperature range of FusionModule800 is -40-45 degrees, and the operating temperature range of FusionModule500 is 0~45 degrees ( )
- A. True
- B. False
Answer: B
NEW QUESTION # 68
The communication between the NetEco management system and the ECC800 collector adopts Huawei's proprietary protocol BIN protocol. ( ).
- A. False
- B. True
Answer: B
NEW QUESTION # 69
Huawei precision air conditioners have power supply overvoltage, undervoltage alarm and fault diagnosis alarm recording functions, automatic protection, automatic recovery, automatic restart and other functions. ( )
- A. False
- B. True
Answer: B
NEW QUESTION # 70
What is the maximum IT load and how many power modules can the FusionModule2000 integrated UPS support?
- A. 125KW, 5 25KVA power modules
- B. 125KW, 6 25KVA power modules
- C. 150KW, 6 25KVA power modules
- D. 150KW, 7 25KVA power modules
Answer: B
NEW QUESTION # 71
The NetEco6000 management system can provide the following access control card readers for installation on the door of the computer room? (Multiple choices)
- A. Swipe fingerprint reader
- B. Swipe card password fingerprint reader
- C. Swipe PIN Reader
- D. IC card reader
Answer: A,B,C,D
NEW QUESTION # 72
Fusion800 has the function of self-starting of civil air conditioner
- A. True
- B. False
Answer: B
NEW QUESTION # 73
For an IT load of 80kW, a UPS system of 80kVA can meet the basic needs.
- A. True
- B. False
Answer: B
NEW QUESTION # 74
Neteco supports centralized management of multiple data centers ( )
- A. False
- B. True
Answer: B
NEW QUESTION # 75
The main circuit input voltage range of UPS2000-G- (6K-20K) models of each capacity is 80V~ 280V, and the input frequency range is 40Hz-70Hz. The ultra-wide input range can effectively reduce the number of battery switching, avoid fault-prone areas, reduce Battery charge and discharge times to extend battery life. ( )
- A. False
- B. True
Answer: B
NEW QUESTION # 76
UPS2000-G-(6K- 20K) has a strong lightning protection design in the industry, lightning protection level ( ), surge protection level ( ), can avoid 90 failures caused by lightning strikes, and reliably protect the exchange of back-end equipment. input port.
- A. 2kA; 4kV
- B. 5kA; 6kV
- C. 4kA; 6kV
- D. 2kA; 6kV
Answer: B
NEW QUESTION # 77
Which options are there for the video frame storage time of FusionModule500&FusionModule800?
- A. three months
- B. a week
- C. a month
Answer: B,C
NEW QUESTION # 78
In Fusionmodu1le2000, each subsystem linkage strategy can be manually configured. ( )
- A. False
- B. True
Answer: B
NEW QUESTION # 79
......